PM-3133

SKU 3974

ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for three-phase power measurement. With its high accuracy (<0.5%, PF=1 ), the PM-3000 series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 200 A). It operates over a wide input voltages range 10 ~ 500 VAC which allows worldwide compatibility. And with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus RTU, Modbus TCP or CAN bus protocols for easy integration.

See the Product PDF Datasheet for Full Specifications

  • True RMS Power Measurements
  • Energy Analysis for 3P4W, 3P3W, 1P3W, 1P2W
  • Current Measurements Up to 200 A with Different CT Ratio
  • Voltage Measurements Up to 500 V
  • Clip-on CT for Easy Installation
  • W Accuracy Better than 0.5% (PF=1)
  • Supports RS-485, Ethernet or CAN bus Interface
  • Supports Modbus RTU, Modbus TCP or CANopen Protocol
  • Supports 2 Power Relay Output (Form A)
  • RS-485 Interface
    PM-3133P: Modbus RTU, 3-phase power meter (Without CTs, the PM-3133P should be directly connected to the 333mV CT)
    PM-3133-100: Modbus RTU, 3-phase power meter; includes 60A CT (Inside diameter 10mm; wire lead 1.8m) x 3
    PM-3133-160: Modbus RTU, 3-phase power meter; includes 100A CT (Inside diameter 16mm; wire lead 1.8m) x 3
    PM-3133-240: Modbus RTU, 3-phase power meter; includes 200A CT (Inside diameter 24mm; wire lead 1.8m) x 3
    PM-3133-100P: Modbus RTU, 3-phase power meter; includes 60A CT (Inside diameter 10mm; wire lead 4m) x 3
    PM-3133-160P: Modbus RTU, 3-phase power meter; includes 100A CT (Inside diameter 16mm; wire lead 4m) x 3
    PM-3133-240P: Modbus RTU, 3-phase power meter; includes 200A CT (Inside diameter 24mm; wire lead 4m) x 3
    PM-3133-360P: Modbus RTU, 3-phase power meter; includes 300A CT (Inside diameter 36mm; wire lead 4m) x 3
    PM-3133-400P: Modbus RTU, 3-phase power meter; includes 400A CT (Inside diameter 36mm; wire lead 4m) x 3

 

  • Ethernet Interface
    PM-3133P-MTCP: ~ Available soon ~ Modbus TCP, 3-phase power meter (Without CTs. The PM-3133P-MTCP should be directly connected to the 333mV CT)
    PM-3133-100-MTCP: Modbus TCP, 3-phase power meter; includes 60A CT (Inside diameter 10mm; wire lead 1.8m) x 3
    PM-3133-160-MTCP: Modbus TCP, 3-phase power meter; includes 100A CT (Inside diameter 16mm; wire lead 1.8m) x 3
    PM-3133-240-MTCP: Modbus TCP, 3-phase power meter; includes 200A CT (Inside diameter 24mm; wire lead 1.8m) x 3
    PM-3133-360P-MTCP: Modbus TCP, 3-phase power meter; includes 300A CT (Inside diameter 36mm; wire lead 4m) x 3
    PM-3133-400P-MTCP: Modbus TCP, 3-phase power meter; includes 400A CT (Inside diameter 36mm; wire lead 4m) x 3

 

  • CANopen Interface
    PM-3133-100-CPS: CANopen, 3-phase power meter; includes 60A CT (Inside diameter 10mm; wire lead 1.8m) x 3
    PM-3133-160-CPS: CANopen, 3-phase power meter; includes 100A CT (Inside diameter 16mm; wire lead 1.8m) x 3
    PM-3133-240-CPS: CANopen, 3-phase power meter; includes 200A CT (Inside diameter 24mm; wire lead 1.8m) x 3
    PM-3133-360P-CPS: ~ Available soon ~ CANopen, 3-phase power meter; includes 300A CT (Inside diameter 36mm; wire lead 4m) x 3
    PM-3133-400P-CPS: ~ Available soon ~ CANopen, 3-phase power meter; includes 400A CT (Inside diameter 36mm; wire lead 4m) x 3
  • ICP DAS